Using Web Interface to Manage the Access Point AP-800 User Guide
Configuring the Device
67
Figure 6-18 QoS EDCA Tables
2. Click Edit and configure the following parameters in each table:
• Access Category: It is a read-only parameter and indicates the Access Category being defined:
— Background
— Best Effort
—Video
—Voice
Figure 6-19 Default EDCA Parameters for Station and AP
• CWMin: Minimum Contention Window.
— Configurable range for Station is between 0 to 32767
— Configurable range for AP is between 0 to 32767
Class of
Service
Default EDCA Parameters for Station
Default EDCA Parameters for AP
CWMin CWmax AIFS TXOP(unsigned
integer)
CWMin CWmax AIFS TXOP(unsigned
integer)
Back
Ground
15 1023 7 0 15 1023 7 0
Best
Effort
15 1023 3 0 15 63 3 0
Video 7 15 2 3.008 ms 7 15 1 3.008 ms
Voice 3 7 2 1.504 ms 3 7 1 1.504 ms