Command Line Interface (CLI) AP-700 User Guide
Parameter Tables
179
SNTP Parameters
Link Integrity Parameters
Link Integrity IP Target Table
Name Type Value Access CLI Parameter
SNTP Group Group N/A R sntp
SNTP Status Integer enable
disable
RW sntpstatus
Primary Server Name or
IP Address
DisplayString 0 - 255 characters RW sntpprisvr
Secondary Server Name
or IP Address
DisplayString 0 - 255 characters RW sntpsecsvr
Time Zone Integer See MIB for
requirements
RW sntptimezone
Daylight Savings Time Integer -2
-1
0
+1
+2
RW sntpdaylightsaving
Year Integer32 N/A RW sntpyear
Month Integer32 1 - 12 RW sntpmonth
Day Integer32 1 - 31 RW sntpday
Hour Integer32 0 - 23 RW sntphour
Minutes Integer32 0 - 59 RW sntpmins
Seconds Integer32 0 - 59 RW sntpsecs
Addressing Format Integer ipaddress
name
RW sntpaddrfmt
Name Type Value Access CLI Parameter
Link Integrity* Group N/A R linkint
Link Integrity Status* Integer enable
disable (default)
RW linkintstatus
Link Integrity Poll Interval* Integer 500 - 15000 ms
(in increments of 500ms)
500 ms (default)
RW linkintpollint
Link Integrity Poll
Retransmissions*
Integer 0 - 255
5 (default)
RW linkintpollretx
Name Type Value Access CLI Parameter
Link Integrity IP Target Table Table N/A R linkinttbl
Table Index Integer 1 - 5 N/A index
Target IP Address IpAddress User Defined RW ipaddr
Comment (optional) DisplayString User Defined (up to 254
characters)
RW cmt
Status (optional) Integer enable
disable (default)
delete
RW status
Vista de pagina 178
1 2 ... 174 175 176 177 178 179 180 181 182 183 184 ... 220 221

Comentarios a estos manuales