Proxim MP11 5012-SUR Guía de instalación Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 24
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
Page 12 Copyright © 2007 Proxim Wireless
Step 4: View LEDs/Adjust Mounting
LEDs are located in the cable compartment.
When the unit is powered on, the 5012-SUR performs startup diagnostics.
When startup is completed, the LEDs show the operational state of the 5012-
SUR.
The following table shows the status of the LEDs when the 5012-SUR is
operational.
Status Power Wireless Link Ethernet Link
Starting up Three red blinks
followed by
temporary solid
amber
N/A N/A
Radio scanning US: Blinking
amber/green or
amber/yellow
EU/WD: Blinking
green or yellow
N/A N/A
WORP link is up US: Solid green
or yellow
EU/WD: Solid
green or yellow
Blinking green or
yellow
Off: No Ethernet
Solid amber: 10
Mbps
Solid green or
yellow: 100 Mbps
No WORP link US: Blinking
amber/green or
amber/yellow
EU/WD: Blinking
green or yellow
N/A Off: No Ethernet
Solid amber: 10
Mbps
Solid green or
yellow: 100 Mbps
Vista de pagina 11